CPCI-D300 Test bed Configuration and Results

    Test Configuration and Equipment
    Requirements
  • A1…A5 - ammeters, type M-1107 or equivalent, accuracy ±0,1%
  • V1…V5 - voltmeters, type FLUKE 77 or equivalent, accuracy ±0.3%
  • RL1 - electronic load, Kikusui Electronic type PLZ 300W or equivalent
Fig. 1 - Test Pad Schematic


NOTE:   For multiple CPCI-D330 units under test, Red and Blue lines each exhibit tested extremes. Normally, performance graphs for bulk majority of CPCI-D330 Modules examined lay in the middle between the limits depicted with Red and Blue.



Fig. 2 - Efficiency vs Load graphs for Module with 48VDC input


Fig. 3a - Load Regulation vs Output Current graphs for 3.3V channel with 48VDC input voltage


Fig. 3b - Load Regulation vs Output Current graphs for 5V channel powered with 48VDC input voltage


Fig. 3c - Load Regulation vs Output Current graphs for 12V channel powered with 48VDC input voltage


Fig. 4a - Line Regulation vs Input Voltage graphs for 3.3V channel providing a 15ADC output current


Fig. 4b - Line Regulation vs Input Voltage graphs for 5V channel providing a 15ADC output current


Fig. 4c - Line Regulation vs Input Voltage graphs for 12V channel providing a 3ADC output current